After AWR baseline statistics are
computed for a particular baseline, you can set metric thresholds specific to
your baseline.
Compute baseline statistics
directly from the Baselines page (as previously discussed). Then go to the AWR
Baseline Metric Thresholds page and select the type of metrics that you want to
set. When done, select a specific metric and click Edit Thresholds.
On the corresponding Edit AWR
Baseline Metric Thresholds page, specify your thresholds in the Thresholds
Settings section, and then click Apply Thresholds.
You can specify thresholds based on
the statistics computed for your baseline. This is illustrated in the slide. In
addition to “Significance Level,” the other possibilities are “Percentage of
Maximum” and “Fixed Values.”
Note: After a
threshold is set using Baseline Metric Thresholds, the previous threshold
values are forgotten forever and the statistics from the associated baseline
are used to determine the threshold values until they are cleared (by using the
Baseline Metric Threshold UI or PL/SQL interface).